Product Brief
• Model: TH110D20NZ-6, 110V DC high-frequency rectifier module
• Adopts LLC resonant soft-switching digital control technology
• Rated output: DC110V, 20A, 4400W
• Designed for 110V DC power panel and battery charging system
• Support multi-module parallel & N+1 redundant operation
• RS485 Modbus RTU for remote monitoring
• Hot-swappable, standard 19-inch rack pluggable design
• Built-in full protection for stable and safe power supply

Product Parameters
| Item | Specification |
|---|---|
| Model | TH110D20NZ-6 |
| Input | 3-phase 3-wire AC 323~456V |
| Input Frequency | 50Hz±10% |
| Power Factor | ≥0.94 |
| Rated Output | DC110V, 20A, 4400W |
| Adjustable Output Voltage | 88~150VDC |
| Efficiency | ≥95% |
| Voltage Regulation Accuracy | ≤±0.5% |
| Current Regulation Accuracy | ≤±1% |
| Output Ripple Coefficient | ≤0.1% |
| Current Sharing Imbalance | <±3% |
| Cooling | Intelligent temperature-controlled fan cooling |
| Communication | RS485, Modbus RTU |
| Operating Temperature | -10℃ ~ +45℃ |
| Relative Humidity | ≤90% (non-condensing) |
| Max Altitude | ≤2000m |
| Noise | ≤55dB |
| Dimension | 22084320 mm |
| Protection | Input over/under voltage, output overvoltage, overcurrent, short circuit, overtemperature, fan fault |
| Installation | Standard 19-inch rack, hot-swappable |
Product Advantages
• High efficiency up to 95%, LLC soft switching, low heat loss
• High precision output with low ripple, extend battery life
• Excellent automatic current sharing, support N+1 redundancy
• Hot-swappable, maintenance without system power off
• Full digital control, remote monitoring & parameter setting
• Comprehensive multi-layer protection for module and load
• Standard 19-inch pluggable structure, easy installation

Application Scenarios
• Substation 110V DC power panel
• Industrial control backup power supply
• Railway & tunnel signal power system
• Communication equipment room DC power system
• Oil, gas, mining and water treatment critical power
• VRLA / gel / lithium battery charging


FAQ
Q1: Can multiple TH110D20NZ-6 modules run in parallel?
A: Yes. It supports parallel connection with automatic current sharing, imbalance less than ±3%. N+1 redundant configuration is available.
Q2: Does it support hot swap?
A: Yes. Hot swap function is supported. You can replace the faulty module without shutting down the whole DC system.
Q3: What communication protocol is used?
A: RS485 interface with Modbus RTU protocol, compatible with most DC monitoring units for remote data reading and fault alarm.
Q4: What types of batteries can it charge?
A: Suitable for 110V system VRLA lead-acid battery, gel battery and matched lithium battery packs. It supports float charge and equalize charge.
Q5: Can it adapt to unstable AC grid?
A: The three-phase AC input range is 323~456V. It has input over/undervoltage protection to adapt to grid fluctuation in industrial and remote areas.